Home · Error codes · Ge · Dishwashers · C4

C4 — Double Fill After Power Failure or Float Issue

critical

The machine filled twice after a power failure, or the float switch is stuck or failed, or a clogged drain or sump is present.

Common causes

  • Power failure caused double fill
  • Float switch stuck or failed
  • Clogged drain or sump area

How to fix it

  • Press Start then Cancel/Reset
  • Tap the float cover to free a stuck float (front left corner of tub floor)
  • Check sump area at back bottom of tub for debris
  • Contact service if issue persists

Parts you might need

  • float switch
  • float cover
  • sump filter
Find replacement parts →
Compiled from Ge's public support resources — original page. Recalled.co is not affiliated with Ge. Report incorrect information at hello@recalled.co.